Page 4
Image 4
ADJUSTMENTS

9b

With correct washers in place (see Step 9a), tighten COUPLING NUT 1/4 turn

10

ADJUSTMENTS

TOP

ARM

 

 

 

 

NIPPLE

 

 

REFILL

 

 

TUBE

TANK

 

 

 

 

LEVER

CRITICAL LEVEL

 

 

MARK ("C.L.")

 

 

MUST BE

 

 

1" ABOVE

 

 

OVERFLOW PIPE

 

 

FLOAT

 

Fig. 10A

CUP

 

FILL

 

 

VALVE

 

 

WATER LEVEL

 

 

ADJUSTMENT

 

 

CLIP

LINK

 

VALVE

ADJUSTABLE

 

BODY

 

HEIGHT

 

 

 

 

SHANK

 

 

WASHER

 

LOCK NUT

THREADED

 

 

SHANK

 

CONE WASHER

 

 

 

PARTS FOR WATER

 

COUPLING NUT

CONNECTION

 

(SEE STEP 9)

 

(HAND TIGHT ONLY)

 

 

Diagram 1

 

 

beyond hand tight.

DO NOT OVERTIGHTEN.

a.Adjust water level. Water level should be adjusted to level indicated in tank by adjusting float cup. See Step 11 for water level adjustment method.

IMPORTANT:

b.If bowl fails to siphon, an adjustment may be required with the lift chain. Simply remove the bead chain from the retainment clip (see Fig. 10A) and take up slack on the chain, and reinsert on lift rod. Make sure the chain is not too taught.

11

Turn on water supply.

12

CARE AND CLEANING

 

 

 

 

Adjust water to water

 

 

 

level specified in the tank

 

When cleaning your toilet, wash it with mild, soapy water, rinse

 

by squeezing water level

 

 

 

thoroughly with clear water and dry with a soft cloth.

 

adjustment clip and

 

 

 

 

 

moving FLOAT CUP up

!

WARNING: Do not use in-tank cleaners. These products can

 

or down along stainless

 

 

seriously damage fittings in the tank. This damage can cause leakage

 

steel link.

 

 

 

and property damage.

 

 

 

 

 

 

American Standard shall not be responsible or liable for any

 

 

 

damage caused by the use of in-tank cleaners.

13

TROUBLE SHOOTING FLUSH VALVE:

13a

REFILL TUBE REPLACEMENT:

SEAL REPLACEMENT:

1.Disconnect Chain.

2.Lift float up and remove flush valve seal by pulling seal out of groove and sliding up over float.

3. Reverse procedure to install new seal.

Locate bottom portion of

hose clip between the ribs (2)

 

 

 

 

on bottom of funnel inlet.

FLOAT

FLUSH

Note: Rotate funnel to position

ribs at rear of the tank.

VALVE

 

SEAL

 

NOTE: DO NOT ADD ANY FOREIGN MATERIALS

TO THE SEALING SURFACE.

- 4 -

730529-100 Rev. M

Page 4
Image 4