11 INSTALL HANDLES
Push ADAPTER (1) on VALVE STEM (2), so that the hole of the ADAPTER (1) without a spline is facing up. Fig. A. Tighten STEM SCREW (3) to secure ADAPTER (1).
Find correct position of LEVER HANDLE ASSEMBLY (4) by adjusting male teeth on ADAPTER (1) to female teeth in HANDLE (4).
Thread LEVER HANDLE ASSEMBLY (4) onto DECK ADAPTER (5) until snug against mounting surface.
Fig. A.
SPLINE END DOWN
4
TOP
THREAD ON
TO DECK
ADAPTER
1
3
2
5
12 TEST INSTALLED FITTING | 5 | 1 |
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
3
Operate both HANDLES (1) to flush water |
|
lines thoroughly. | 1 |
|
Rotate TRANSFER VALVE (5) from rim wash to spray several times to check operation.
13 CHECK DRAIN CONNECTIONS
Pull up
Push
if necessary.
2
4
SPRAY
2
14 EverClean™ Finish Care Instructions
American Standard’s EverClean finish will wipe clean with a soft, dry cloth.
A soft cloth with clean water may also be used, if desired. No additional cleaning products are required.
DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.
15 SERVICE
To change direction of handle rotation, proceed as follows:
| Turn valve to OFF position. Unthread HANDLE | UNTHREAD |
|
| |
|
| |
| BASE (1) from DECK ADAPTER (2). | 1 |
| Pull HANDLE ASSEMBLY off VALVE STEM (3). | |
| ||
| ||
| Remove SPRING CLIP (4). Lift STOP WASHER (5), | |
| ||
| ||
| turn 90˚ and replace. Replace SPRING CLIP (4). |
|
| Find correct position of HANDLE ASSEMBLY by adjusting | |
| ||
|
| male teeth on VALVE STEM (3) to female teeth in HANDLE. | ||||
| Thread HANDLE ASSEMBLY onto DECK ADAPTER (2) | ||||
| |||||
| until snug against mounting surface. | 4 |
|
| |
If spout drips, operate handles several times from |
|
| |||
2 |
|
|
| ||
|
|
| |||
OFF to ON position. Do not force - handles turn |
|
|
|
|
only 90˚.
HANDLE
ASSEMBLY
90˚ | 3 |
| 5 |
M 9 6 8 8 9 4
4