11 INSTALL HANDLES

Push ADAPTER (1) on VALVE STEM (2), so that the hole of the ADAPTER (1) without a spline is facing up. Fig. A. Tighten STEM SCREW (3) to secure ADAPTER (1).

Find correct position of LEVER HANDLE ASSEMBLY (4) by adjusting male teeth on ADAPTER (1) to female teeth in HANDLE (4).

Thread LEVER HANDLE ASSEMBLY (4) onto DECK ADAPTER (5) until snug against mounting surface.

Fig. A.

SPLINE END DOWN

4

TOP

THREAD ON

TO DECK

ADAPTER

1

3

2

5

12 TEST INSTALLED FITTING

With HANDLES (1) in OFF position, turn on WATER SUPPLIES (2) and check all connections for leaks.

Operate both HANDLES (1) to flush water lines thoroughly.

Rotate TRANSFER VALVE (5) from rim wash to spray several times to check operation.

13 CHECK DRAIN CONNECTIONS

OUTLINE OF BIDET

3

1

1

Pull up POP-UP KNOB (3) and fill Bidet with water. Check

that DRAIN STOPPER (4) makes a good seal and retains4 water in Bidet. If STOPPER (4) does not seal properly,

please refer to “Troubleshooting Guide” in these instructions.

Push POP-UP KNOB (3) down and check all drain connections and "P" trap for leaks. Tighten

if necessary.

2

2

SPRAY

14 EverClean™ Finish Care Instructions

American Standard’s EverClean finish will wipe clean with a soft, dry cloth.

A soft cloth with clean water may also be used, if desired. No additional cleaning products are required.

DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.

15 SERVICE

To change direction of handle rotation, proceed as follows:

 

Turn valve to OFF position. Unthread HANDLE

UNTHREAD

 

 

 

 

 

BASE (1) from DECK ADAPTER (2).

1

 

Pull HANDLE ASSEMBLY off VALVE STEM (3).

 

 

 

Remove SPRING CLIP (4). Lift STOP WASHER (5),

 

 

 

turn 90˚ and replace. Replace SPRING CLIP (4).

 

 

Find correct position of HANDLE ASSEMBLY by adjusting

 

 

 

male teeth on VALVE STEM (3) to female teeth in HANDLE.

 

Thread HANDLE ASSEMBLY onto DECK ADAPTER (2)

 

 

 

until snug against mounting surface.

4

 

 

If spout drips, operate handles several times from

 

 

2

 

 

 

 

 

 

OFF to ON position. Do not force - handles turn

 

 

 

 

only 90˚.

HANDLE

ASSEMBLY

90˚

3

 

5

M 9 6 8 8 9 3

4

Page 4
Image 4
American Standard 7038.400 Install Handles, Test Installed Fitting, Check Drain Connections, Service