American Standard 7056.215, 7055.105 Maintenance, MAKE WATER SUPPLY CONNECTIONS Fig, Installation

Models: 7055.105 7055.115 7056.205 705.205 7056.215 705.215 7056.105 7056.115

1 9
Download 9 pages 29 Kb
Page 4
Image 4
3MAKE WATER SUPPLY CONNECTIONS; Fig. 2

3MAKE WATER SUPPLY CONNECTIONS; Fig. 2

1.Turn off hot and cold water supplies before beginning.

2.Connect HOSE ADAPTERS (3) to wall supplies (if

required). Connect FLEXIBLE SUPPLIES (1, 2) directly to HOSE ADAPTERS (3).

3.Connect left supply (Marked with a Red Stripe) to Hot and right supply (Marked with Blue Stripe) to Cold supply. Use adjustable

wrench to tighten connections. Do not over tighten.

4.Faucet supplies are 18" long from faucet base.

Note; If additional supply length is required, installer must purchase those parts separately.

Fig. 2

2

1 4INSTALL OPTIONAL MIXING VALVE; Fig. 3For 7055.105/115 & 7056.105/115 Faucets.InstallationMAINTENANCE1HANDWASH SENSOR OPERATION; Fig. 1Detection Zone: 2" - 10" (50.8mm - 254mm)

3 Manual backgroundManual background

SEAL WASHER (SUPPLIED)

HOT

COLD

Important; If SUPPLY HOSES (1, 2) are too long, loop as illustrated to avoid kinking.

4INSTALL OPTIONAL MIXING VALVE; Fig. 3

For 7055.105/115 & 7056.105/115 Faucets.

Note; For complete detailed installation and operating instructions see installations instructions supplied with mixing valve. No. M968808

Fig. 3

No. M968808

Instructions

SELECTRONIC™

 

 

 

Thermostatic Mixing Valve

 

 

605XTMV

 

 

Installation

M968808

Specications

1

 

 

Installation

2

 

 

Adjust Temperature

3

 

 

Service

3

 

Certified to comply with ASME A112.18.1M

Replacement Parts

4

 

© 2005 American Standard

 

 

NOTE TO INSTALLER: Please give this manual to the customer after installation.

To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S.

customer's e-mail us at: faucetsupport@amstd.com

For Parts, Service, Warranty or other Assistance,

please call 1-800-442-1902 (In Canada: 1-800-387-0369)

(In Toronto Area only: 1-905-3061093)

MAINTENANCE

Fig. 1

1HANDWASH SENSOR OPERATION; Fig. 1

REMOVE PROTECTIVE FILM FROM SENSOR EYE

WHEN INSTALLATION IS COMPLETE.

When the Sensor detects a user, the water immediately starts to flow. Water flow will stop two seconds after user is out of sensor range. The off delay allows the user to comfortably move his hands without the flow cycling on to off. As a precaution, a safety timer will turn off the water, after the sensor has been blocked for 59 seconds. The water will stay off until the blockage is removed from the detection zone.

Detection Zone: 2" - 10" (50.8mm - 254mm)

Default: Set at Factory 6" (152.4mm)

DETECTION Manual background ZONE