7CHANGE HOT LIMIT SETTING FROM 95% TO 85%; Fig. 13
1.Remove the FAUCET COVER (1) by unthreading the LEVER SCREW (2) and pulling off the LEVER HANDLE (3). Unthread the FAUCET COVER SCREW
(4) at the back of the FAUCET. Pull FAUCET COVER
(1) up and off. See Fig. 2 in this section.
2.Replace LEVER HANDLE and rotate
3.Pull out LIMITER STOP (1) from the VALVE STEM (2).
4.Rotate LIMITER STOP (1) 180 degrees and insert back onto VALVE STEM (2).
5.Replace FAUCET COVER (1) and LEVER HANDLE
(3). Install LEVER HANDLE SCREW (2), FAUCET COVER SCREW (4) and tighten. See Fig. 2 in this section.
8GENERAL CLEANING; Fig. 14
1.For general cleaning use a damp, soft cloth to clean the spout and the sensor.
2.For cleaning dirt use a soft cloth with diluted dish washing detergent. Wipe the area using a wet cloth and dry using a soft cloth.
CAUTION
Do not scratch the sensor when cleaning.
Avoid using anything that may scratch the spout surface. Never use polishing power, detergent or a nylon scrub brush. They will damage the surface of the spout or Sensor.
2
3
9
8
SLOT
ROTATE 180˚
Fig. 13 | SLOT | 1 |
| ||
|
|
Fig. 14
FAQ'S
Q:How will I know if battery needs to be replaced?
A:Valve does not open and sensor blinks 2 times interrupted by pause for up to 7 days.
Q:Why has the flow rate of the faucet reduced significantly?
A:Check and clean aerator and strainer.
Q:There is no flow out of faucet when I'm in the sensor range?
A:Check sensor. If sensor blinks 2 times interrupted by pause, replace battery, or call 1
Q:What is the normal operating pressure range?
A:Faucet will operate with supply pressures ranging from
7 | M965255 REV. 1.6 |