American Standard 7056.105, 7055.105, 705.205 HOW TO CHANGE SENSOR RANGE Factory set at 6 Fig

Models: 7055.105 7055.115 7056.205 705.205 7056.215 705.215 7056.105 7056.115

1 9
Download 9 pages 29 Kb
Page 5
Image 5
2HOW TO CHANGE SENSOR RANGE; (Factory set at 6") Fig. 2

2HOW TO CHANGE SENSOR RANGE; (Factory set at 6") Fig. 2

1.Setting the Detection Zone (Distance):

Remove the FAUCET COVER (1) by unthreading the LEVER SCREW (2) and pulling off the LEVER HANDLE (3). Unthread the FAUCET COVER SCREW

(4)at the back of the FAUCET. Pull FAUCET COVER

(1)up and off. Fig. 2.

2.Disconnect the BLACK POWER SUPPLY CONNECTOR (1) and reconnect. Fig. 3.

3.While the SENSOR CONTROL LED (2) is blinking slowly, place your hand 1 - 2 in. (25.4-50.8mm) in front of the sensor. Fig. 4.

4.When the LED stops blinking and stays "ON", move your hand to the desired position and hold in place until the LED begins to blink again. Fig. 4a.

5.Once the SENSOR CONTROL LED (2) begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set.

6.Replace FAUCET COVER (1) and LEVER HANDLE

(3). Install LEVER HANDLE SCREW (2), FAUCET COVER SCREW (4) and tighten. Fig. 2.

Fig. 2

REMOVE

Fig. 4a 1

REPLACE Manual background

 

3

4

2

 

Fig. 3

1

 

Fig. 4

1"-2"

(25.4mm- 50.8mm)

2 BLINKING LED

Fig. 4a

UP

TO

10"

 

 

 

(254mm)

2 BLINKING LED

4

M965255 REV. 1.6

 

Page 5
Image 5
American Standard 7056.105, 7055.105, 705.205, 7055.115, 705.215, 7056.215 HOW TO CHANGE SENSOR RANGE Factory set at 6 Fig