Draft Hood/Damper Installation

Do not operate water heater with damper in closed position, it must be in the open position during water heater operation.

Do not negate the action of any existing safety or operational controls.

Install the supplied draft hood and damper on the flue outlet collar. Use only the supplied draft hood and damper, DO NOT use any substitute or alter the components in any way.

Place the damper on the water heater (see figure 3A). Align the four pilot holes on top of the water heater with the 4 corresponding holes on the damper bracket and secure with the supplied screws. Next, align the draft hood legs with the 4 corresponding pilot holes on top of the water heater and attach securely with the supplied screws. Locate the wiring from the ECO, and attach it to the wiring harness on the damper (see Figure 3A). Once damper is installed, ensure that the damper posi- tion indicator is visible (See figure 3A).

Figure 3A: Flue Damper Assembly

Bracket screws

Draft hood

 

 

Draft hood screws

Damper motor

Damper wiring harness

ECO wiring harness

 

Damper position indicator

Damper motor

 

Damper wiring harness

Damper in OPEN position

9

Flue Outlet Reducer

Some units are shipped with a flue outlet reducer (See Figure 3B). Use only the flue outlet reducer supplied with this unit. The flue outlet reducer should be connected to the top of the flue damper and sealed by high temperature silicon.

The vent pipe must be installed according to all local and state codes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-latest edition.

Figure 3B: Flue Outlet Reducer

High

Flue outlet reducer

temperature

 

silicon sealant

 

Damper motor

 

Damper wiring harness

 

Damper in OPEN position