CN 211/215 UIM Communication Cable:

Pin 1 - +5 V
Pin 2 - +12 V
Pin 3 - Signal A+
Pin 4 - Signal B+
Pin 5 - Ground
Note: Both CN211 and CN215 are identical and either can be used for the UIM communication.

CN 208 Overload Detection:

Pin 1 - High pressure switch.
Pin 2 - High pressure switch.
Pin 3 - Low pressure switch.
Pin 4 - Low pressure switch.
Pin 5 - Not used
Pin 6 - Not used
Pin 7 - Not used
Pin 8 - Not used
Pin 9 - Condensate pump signal over ow (optional)
Pin 10 - Condensate pump signal over ow (optional)
Note: Pin 9 and 10 are connected by a jumper wire. This wire should be cut and wired in series to
the over ow switch of the eld supplied condensation pump (optional).

SW 201 Dip Switch:

SW 1 - Not used
SW 2 - Not used
SW 3 - Not used
SW 4 - Not used

Led 201 Power Indicator:

LED 201 when illuminated, indicate that 5 and 12 Volts DC are present for the UIM

Section D

LED 202/203 Powered Anode Indicators:
• LED 202-
One (1) ash/second (approx.), indicates
there is power to the anode circuit.
• LED 203-
Two (2) ashes/second (approx.), indicates
proper operation.
Four (4) ashes/second (approx.),
indicates a fault.

Figure 9

LED

203 / 202

Section D

Section “C” of Control Board (con’t)