Programming Information

Send_Commands (Cont.)

?CTON

Sends the current on-time pulse string "'CTON',<Time>" to the master.

 

Set the <Time> value in .10 second increments.

 

Example:

 

SEND_COMMAND 92,'?CTON'

 

Sends the current on-time pulse string from device 92 to the master.

 

 

'DC',<IR in>,<IR out>

Sets a direct connection so the <IR out> (IR function) data transmits

 

while the <IR in> code is received. The PUSH and RELEASE for the

 

<IR in> code is not sent to the master. The maximum number of direct

 

connections is 16.

 

Variables:

 

<IR in> = Custom IR function assigned to hand-held IR transmitting

 

device

 

<IR out> = IR functions (see theIR Functions (Standard Order) table

 

on page 16)

 

Example:

 

SEND_COMMAND 26,"'DC',145,24"

 

Increases the volume level on the equipment connected to device 26.

 

 

'DE',<Time>

Sets the delay time in .10 second increments for the TV sensor (CC-IR)

 

to stabilize before sensing for a status change.

 

Variable:

 

<Time> = 0-255; System default time = 10 (1 second).

 

Example:

 

SEND_COMMAND 25,"'DE',10"

 

Sets the delay time to 1 second for the CC-IR connected to device 25.

 

 

?DE

Sends the current television power sensor (CC-IR) delay time string

 

"'DE',<Time>" to the master.

 

Set the <Time> value in .10 second increments.

 

Example:

 

SEND_COMMAND 25,'?DE'

 

Device 25 sends the current television power sensor delay time to the

 

master.

 

 

DK

Deletes all direct connections set with the 'DC' command.

 

 

POD

Disables current 'PON' (power on) or 'POF' (power off) command set-

 

tings. Channel 255 changes are enabled.

 

 

POF

Sends IR function 28 (if available) or 9 to turn device power off. After

 

three attempts, if the CC-IR (TV sensor) still detects a power-on status,

 

the television controller starts processing stored buffer commands.

 

Then, if another IR function 28 or 9 fails to turn the television's power off,

 

the television controller sends a PUSH and RELEASE to channel 248

 

and generates a power failure error. If the device is turned on manually,

 

this command turns television power off unless the television controller

 

receives a 'PON' (power on) or 'POD' (disable 'POF') command.

 

 

PON

Sends IR function 27 (if available) or 9 to turn device power on. After

 

three attempts, if the TV sensor (CC-IR) still detects a power-off status,

 

the television controller starts processing stored buffer commands.

 

Then, if another IR function 27 or 9 fails to turn the television's power on,

 

the television controller sends a PUSH and RELEASE to channel 248

 

and generates a power failure error. If the device is turned off manually,

 

this command turns television power on unless the television controller

 

receives a 'POF' (power off) or 'POD' (disable 'PON' command) com-

 

mand.

 

 

18

AXB-TC and AXB-TCR Television Controllers (& Receivers)

Page 22
Image 22