Installation and Wiring
IR Emitter connections
Connect the
Television
IR EMITTER | GND |
connector | SG |
|
FIG. 3 CC-IRC IR Emitter connector wiring diagram
Axlink data and power connections
Connect the Central Controllers's AXlink connector to the AXlink connector on the rear panel of the television controller for data and 12 VDC power, as shown in FIG. 4.
12 VDC PWR connector
PWR
GND
PWR
AXP
AXlink connector
AXM
GND
no connection
PWR
AXP
Axcess Control System
AXM
GND
FIG. 4 AXlink data and power wiring diagram
Axlink data and 12 VDC power supply connections
Connect the Central Controller’s AXlink connector to the AXlink connector on the rear panel of the television controller, and the optional 12 VDC power supply, as shown in FIG. 5.
12 VDC PWR connector
PWR
GND
PWR
AXP
AXlink connector
AXM
GND
12 VDC power supply
PWR
AXP
Axcess Control System
AXM
GND
FIG. 5 AXlink Data and 12 VDC Power Supply Connections
Use the 12 VDC power supply when the distance between the AMX system and television controller exceeds the limits described in the Wiring Guidelines table on page 7.
8 |
|