Installation and Wiring
Installation and Wiring
Setting the Device DIP Switch
The
DIP Switch Settings
Switch | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
|
|
|
|
|
|
|
|
|
Value | 1 | 2 | 4 | 8 | 16 | 32 | 64 | 128 |
|
|
|
|
|
|
|
|
|
DEVICE
1 2 3 4 5 6 7 8 ON
Internal Jumper Settings
The internal jumpers, located on the circuit card inside the television controller enclosure, set the input, output, and IR attenuation modes. Internal jumper modes include:
Jumper JP1 sets the input mode for power sensing or power current sensing.
Jumper JP2 sets the IR output mode for IR or serial communication.
Jumper JP3 sets the IR attenuation mode for bypass or adjustment.
Use a
Static electricity can damage electronic circuitry. Before removing the enclosure, discharge any accumulated static electricity from your body by touching a grounded metal object.
1.Unplug all connectors from the rear panel of the television controller.
2.Remove the two
3.Pull the two enclosure halves apart and set the bottom portion of the enclosure on a flat surface. FIG. 1 shows the location of the internal jumpers.
JP1 jumper
JP3 jumper
JP2 jumper
front
FIG. 1 Internal jumper locations
4.Replace the top portion of the enclosure on the bottom portion. Then, refasten the two
5 | |
|
|