Installation and Wiring
Make sure to connect only the GND wire on the AXlink connector when using a 12 VDC power supply. Do not connect the PWR wire to the AXlink connector's PWR opening.
PCS and Axlink data and power connections
Connect the PCS Power Current Sensor to the TV Sensor connector, on the rear panel of the television controller (FIG. 6) to detect and control the television power status (on or off).
Television
12 VDC | PWR |
connector | GND |
| |
| PWR |
AXlink | AXP |
no connection
PWR
AXP PCS
Controller
connector | AXM |
| |
| GND |
AXM
Power Supply Sensor
TV SENSOR | GND |
connector | SEN |
|
GND
FIG. 6 PCS and AXlink data and power wiring diagram
PCS and 12 VDC power supply connections
Connect the PCS to the TV Sensor connector, on the rear panel of the television controller, and the optional 12 VDC power supply, as shown in FIG. 7, to detect and control the television power status (on or off).
Television Controller
12 VDC | PWR |
connector | GND |
| |
| PWR |
AXlink | AXP |
connector | AXM |
| |
| GND |
TV SENSOR | GND |
connector | SEN |
|
PWR | 12 VDC |
GND | power supply |
| |
PWR |
|
AXP | PCS |
AXM | Power Supply Sensor |
| |
GND |
|
FIG. 7 PCS and optional 12 VDC power supply wiring diagram
9 | |
|
|