Installation and Wiring

Make sure to connect only the GND wire on the AXlink connector when using a 12 VDC power supply. Do not connect the PWR wire to the AXlink connector's PWR opening.

PCS and Axlink data and power connections

Connect the PCS Power Current Sensor to the TV Sensor connector, on the rear panel of the television controller (FIG. 6) to detect and control the television power status (on or off).

Television

12 VDC

PWR

connector

GND

 

 

PWR

AXlink

AXP

no connection

PWR

AXP PCS

Controller

connector

AXM

 

 

GND

AXM

Power Supply Sensor

TV SENSOR

GND

connector

SEN

 

GND

FIG. 6 PCS and AXlink data and power wiring diagram

PCS and 12 VDC power supply connections

Connect the PCS to the TV Sensor connector, on the rear panel of the television controller, and the optional 12 VDC power supply, as shown in FIG. 7, to detect and control the television power status (on or off).

Television Controller

12 VDC

PWR

connector

GND

 

 

PWR

AXlink

AXP

connector

AXM

 

 

GND

TV SENSOR

GND

connector

SEN

 

PWR

12 VDC

GND

power supply

 

PWR

 

AXP

PCS

AXM

Power Supply Sensor

 

GND

 

FIG. 7 PCS and optional 12 VDC power supply wiring diagram

AXB-TC and AXB-TCR Television Controllers (& Receivers)