Wiring and Installation

the receiver or sensor and the Central Controller. The maximum wiring lengths are based on a minimum of 13.5 volts available at the Central Controller's power supply.

Wiring Specifications

Maximum Wiring Length

Wire Size

IR Sensors

IR Receivers

 

 

 

18 AWG

4,696 feet (1431.34 m)

3,354 feet (1022.30 m)

 

 

 

20 AWG

2,970 feet (905.26 m)

2,121 feet (646.48 m)

 

 

 

22 AWG

1,851 feet (564.18 m)

1,314 feet (400.511 m)

 

 

 

24 AWG

1,167 feet (355.70 m)

833 feet (253.90 m)

 

 

 

If you install the IR sensor or receiver farther away from the Central Controller than recommended in the Wiring Specifications table, connect an external 12 VDC power supply, as shown in the wiring diagrams in this section.

Connecting the Wiring

The following paragraphs describe wiring connections using AXlink for data and power, using AXlink plus an external 12 VDC power supply, and wiring the IRX-DM+ or IRX-SM+ to the AMX IR receiver.

Wiring the AXD-IR+ or the AXR-IRSM+ to AXlink

Install the AXlink data/power bus wiring as shown in FIG. 15.

AXlink connector on the AXD-IR+ or the AXR-IRSM+

(-) GND 1

AXM 2

AXP 3

(+) PWR 4

1 GND (-)

2 AXM

3 AXP

4 PWR (+)

Control system

FIG. 15 AXlink wiring

Using the AXlink four-pin connector with an external 12 VDC power supply

Connect the Central Controller's AXlink connector to the AXlink connector on the AXD-IR+ or the AXR-IRSM+ as shown in FIG. 16.

(-) GND 1

1

GND (-)

AXM 2

2

AXM

AXP

3

3

AXP

(+) PWR

4

4

PWR (+)

AXlink connector on the AXD-IR+ or the AXR-IRSM+

12 VDC power supply

PWR (+)

GND (-)

Control system

FIG. 16 AXlink wiring diagram using an external 12 VDC power supply

IR Sensors and Receivers

11

 

 

 

 

Page 15
Image 15
AMX instruction manual Connecting the Wiring, Wiring Specifications, Wiring the AXD-IR+ or the AXR-IRSM+ to AXlink