Wiring and Installation

!To receive 455 kHz, position the jumper (both jumpers on the receivers) on the left two pins, pins 1 and 2, away from the edge of the circuit boards, to receive 455 kHz. (This is the default setting.)

!To receive 38 kHz, position the jumper (both jumpers on the receivers) on the right two pins, pins 2 and 3, near the edge of the circuit boards, to receive 38 kHz.

 

 

 

 

 

 

IR SNSR

 

 

 

 

 

 

IR SNSR

 

 

 

 

 

 

38/455

 

 

 

 

 

 

38/455

 

 

 

 

 

 

kHz

 

 

 

 

 

 

kHz

 

 

 

 

 

 

 

 

 

 

 

Setting for 455 kHz

Setting for 38 kHz (default)

FIG. 10 Receive frequency jumper settings

2.Go on to the next procedure:

!If you are installing a receiver, go on to Configuring the Receivers.

!If you are installing an IR sensor, refer to Sensor IR validation level in Configuring the Receivers before going on to Installation.

Configuring the Receivers

To configure the receivers, set the AXlink device number and the IR validation level.

AXlink Device DIP switch

IR validation jumper pins

AXlink connector

FIG. 11 IR receiver AXlink device DIP switches, IR validation jumper pins, AXlink connector, and receive frequency jumper pin locations

Setting the AXlink Device Number

Perform the following steps to set the receiver's AXlink device number:

1.Locate the eight-position Device DIP switch (FIG. 11).

2.Set the DIP switch according to the DIP switch values shown in FIG. 12.

The device number is set by the total value of DIP switch positions that are ON (down). The Axcess software program in your system typically uses device numbers 128 through 255 for the panels.

Switch

1

2

3

4

5

6

7

8

Value 1 2 4 8 16 32 64 128

 

8

IR Sensors and Receivers

 

 

 

Page 12
Image 12
AMX IR instruction manual Configuring the Receivers, Setting the AXlink Device Number