Wiring and Installation

Use a 12 VDC power supply when the distance between the Central Controller and the sensors or receivers exceeds the limits described in the Wiring Specifications table above. Make sure to connect only the GND wire on the AXlink connector when using a 12 VDC power supply.

Do not connect the PWR wire to the AXlink connector's PWR (+) terminal on the

Central Controller's side

Wiring the IRX-DM+ or IRX-SM+ to the AMX IR Receiver

Wire the IR sensor to the AMX IR receiver as shown in FIG. 17.

AXC-RCVI GND

AXB-TM IN

MX8 AUX

MX16 +12V

GND

IRX-UM+

OUT

or

AUX OUT

IRX-SM+#2

+12

 

GND

IRX-UM+

OUT

or

AUX OUT

IRX-SM+#1

+12

 

FIG. 17 Wiring the IR sensor to the AMX receiver

You can wire up to eight IR sensors in parallel to an AXC-RCVI, AMX Television Manager, MX8, or MX16. For additional information, refer to the reference guides or instruction manuals for those AMX products.

Checking IR Data status

Locate the red IR Data LED on the front of the unit. Point the system's AMX transmitter towards the sensor and press a button. The IR Data LED lights when the unit receives data. If the IR Data LED on the unit does not light:

!Verify that the transmit LED on the transmitter lights when you press a button.

!Check the wiring to the sensor.

!Verify that you configured the transmitter for the proper frequency IR transmission.

Checking AXlink status

The AXlink LED lights to indicate AXlink power/data status as follows:

• One blink per second

indicates power is active and AXlink communication is working.

• Two blinks per second

indicates the devices specified in the Master program do not match

 

the devices found.

• Three blinks per second

indicates AXlink communication error

• Full on

indicates the following conditions:

 

• There is no AXlink control or activity, but power is on.

 

• The Axcess program is not loaded.

 

12

IR Sensors and Receivers

 

 

 

Page 16
Image 16
AMX Wiring the IRX-DM+ or IRX-SM+ to the AMX IR Receiver, Checking IR Data status, Checking AXlink status