Anaheim MDM60001 user manual Fault Protection, Torque/Speed Curves, Over Temperature Protection

Models: MDM60001

1 11
Download 11 pages 52.51 Kb
Page 10
Image 10
FAULT PROTECTION

FAULT PROTECTION

TORQUE/SPEED CURVES

The MDM60001 is internally protected against over temperature, over/under voltage, and short circuits.

The over temperature set point is between 60C and 70EC. Care should be taken when choosing a heatsink so that there is good thermal flow, otherwise hot spots may occur in the MDM60001 which will reduce the effectiveness of the thermal protection.

The short circuit protection consists of PHASE to PHASE, PHASE to GROUND, and +V to PHASE.

In the condition where the DC voltage of the driver drops below +23 volts the driver’s output stage will be disabled. When the driver’s DC voltage rises back above 24 volts, the driver will automatically re-enable the outputs (if previously enabled).

In the condition where the DC voltage of the driver exceeds approximately 82 volts, the driver will execute a fault.

If any fault is detected by the MDM60001, the outputs will be disabled and can not be re- enabled without resetting or powering down the driver. At the same time the open collector FAULT output is turned on.

The FAULT output is non-isolated and has the ability to sustain the maximum driver voltage. It is capable of sinking up to 25mA which can be used to drive a small relay or LED.

OVER TEMPERATURE PROTECTION

The MDM60001 microstepper is a power device and is designed to protect itself from overheating. It does this by monitoring the surface temperature of the drive plate and will automatically shutdown if the temperature reaches 60°C (152°F).

To prevent nuisance shutdowns, proper heatsinking is required to limit the temperature at the drive plate.

A thermal grease or thermal pad should be used between the drive plate and the mounting surface of the heatsink. The fins of the heatsink should be mounted vertically with at least 3" of space below and above the heatsink for efficient cooling.

In some applications fan cooling will be required to maintain the plate temperature below the 60°C shutdown temperature.