CLOCK SIGNALS

Either a crystal or a TTL compatible clock signal can clock the ADSST-218x.

If an external clock is used, it should be a TTL compatible signal running at half the instruction rate. The signal is connected to the processor’s CLKIN input. When an external clock is used, the XTAL input must be left unconnected.

Because the ADSST-218x includes an on-chip oscillator circuit, an external crystal may be used. The crystal should be connected across the CLKIN and XTAL pins, with two capacitors connected as shown in Figure 4. The capacitor values are dependent on the crystal type and should be specified by the crystal manufacturer. A parallel resonant, fundamental frequency, microprocessor grade crystal should be used.

A clock output (CLKOUT) signal is generated by the processor at the processor’s cycle rate. This can be enabled and disabled by the CLKODIS bit in the SPORT0 autobuffer control register.

CLKIN XTAL CLKOUT

DSP

03738-0-003

Figure 4. External Crystal Connections

RESET

The RESET signal initiates a master reset of the ADSST-2185x. The RESET signal must be asserted during the power-up sequence to assure proper initialization. RESET during initial power-up must be held long enough to enable the internal clock

to stabilize. If RESET is activated any time after power-up, the clock continues to run and does not require stabilization time.

The power-up sequence is defined as the total time required for the crystal oscillator circuit to stabilize after a valid VDD is applied to the processor and for the internal phase-locked loop (PLL) to lock onto the specific crystal frequency. A minimum of 2000 CLKIN cycles ensures that the PLL has locked but does not include the crystal oscillator start-up time. During this

power-up sequence, the RESET signal should be held low. On

any subsequent resets, the RESET signal must meet the minimum pulse-width specification, tRSP.

The RESET input contains some hysteresis; however, if an RC circuit is used to generate the RESET signal, the use of an exter- nal Schmitt trigger is recommended.

RECOMMENDED OPERATING CONDITIONS

Table 3.

Parameter

Min

Max

Unit

VDDINT

2.37

2.63

V

VDDEXT

2.37

3.60

V

VINPUT1

VIL = –0.3

VIH = 3.6

V

TAMB

0

70

°C

1The ADSST-2185x is 3.3 V tolerant (always accepts up to 3.6 V max VIH), but voltage compliance (on output, VOH) depends on the input VDDEXT; because VOH (MAX) = VDDEXT (MAX). This applies to bidirectional pins (D0–D23, RFS0, RFS1, SCLK0, SCLK1, TFS0, A1–A13, PF0–PF7) and input only pins (CLKIN, RESET, BR, DR0, DR1, PWD).

Rev. 0 Page 7 of 24