Andrew 7.6-Meter ESA manual Lubrication Chart, Preventive Maintenance, Months

Models: 7.6-Meter ESA

1 69
Download 69 pages 15.91 Kb
Page 67
Image 67

Lubrication Chart

Lube

Components

 

 

Frequency

 

Type

Type

No. of Lube

Point

to be

 

 

 

(Months)

 

 

of

of

Points or

No.

Lubricated

 

1

3

 

6

12

Service

Lube

Quantity

 

 

 

 

 

 

 

 

 

 

 

1.

Elevation Jackscrew Housing

 

 

X

 

 

 

Pressure Fitting

SHC32

1

 

 

 

 

 

 

 

 

 

 

2.1

Elevation Jackscrew Gear Housing

 

 

 

I*

C**

Pipe Plugs

SHC624

10 Oz

 

Fill and Drain

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.2

Elevation Drive Intermediate Gearbox

I*

C**

 

 

 

Pipe Plugs

SHC624

34 Oz.

 

Fill and Drain

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Elevation Jackscrew Pivot Pin, upper

 

X

 

 

 

Pressure Fitting

SHC32

1

 

 

 

 

 

 

 

 

 

 

5.

Azimuth Jackscrew Pivot Pin, front

 

X

 

 

 

Pressure Fitting

SHC32

1

 

 

 

 

 

 

 

 

 

 

 

6.

Azimuth Jackscrew Housing

 

 

X

 

 

 

Pressure Fitting

SHC32

2

 

 

 

 

 

 

 

 

 

 

7.1

Azimuth Jackscrew Gear Housing

I*

C**

 

 

 

Pipe Plugs

SHC624

4 Oz.

 

Fill and Drain

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8.2

Azimuth Drive Intermediate Gearbox

 

 

 

I*

C**

Pipe Plugs

SHC624

34 Oz.

 

Fill and Drain

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9.

Polarization Drive Gear

 

 

 

 

X

 

Brush

SHC32

Minimum Surface

 

 

 

 

 

 

 

 

 

 

 

Coverage

 

 

 

 

 

 

 

 

 

 

 

10.

Feed Rotation Worm Gear

 

 

 

 

X

 

Pressure Fitting

SHC32

2

 

Pillow Blocks

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X = Lubricate

I = Inspect

C = Change

 

 

 

 

 

 

 

*Inspection requires checking for visible signs of oil leakage, draining replacing and adding oil to ensure appropriate oil level requirements. Excessively dirty oil will require fresh oil replacement. If oil leakage is found to be excessive, refer to appropriate troubleshooting information and perform applicable corrective action. Periodic inspection procedures can be less frequent after first or second scheduled inspections.

**Initial oil change requirements include flushing gear boxes with a standard cleaning agent.

1 Type ‘HS’ and ‘STHS’ drives only. 10 oz. required for gearbox on Type ‘MS’ drives. 2 Type ‘HS’ and ‘STHS’ drives only.