VERTICAL CONTACT TOASTER
TROUBLESHOOTING
WARNING
To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip- ment should be performed by qualified service personnel. The unit should be unplugged when servicing, except when electrical tests are required. Use extreme care during electrical circuit tests. Live circuits will be exposed.
Problem | Possible Cause | Corrective Action |
No heat and conveyor | Toaster is installed incor- | Perform installation and operating procedures |
belts do not move. | rectly. | (pages |
| Not enough voltage, defec- | Check receptacle for correct voltage. See |
| tive power cord, defective | Specifications (page 5). |
| rocker switch. | With unit plugged in and rocker switch on, check |
|
| |
|
| for correct voltage into rocker switch. If low or zero |
|
| voltage, replace power cord. If voltage is correct, |
|
| check for correct voltage out of rocker switch. If low |
|
| or no voltage, replace rocker switch. |
| Reset | |
| Wiring problem. | Check all electrical connections for burns, discolor- |
|
| ation or arcing. Replace all connections or compo- |
|
| nents with damaged terminals. Replace all dam- |
|
| aged wiring with the same (or higher) rated wire. |
No heat and conveyor | Wiring problem. | Check all electrical connections for burns, discolor- |
belts move. |
| ation or arcing. Replace all connections or compo- |
|
| nents with damaged terminals. Replace all dam- |
|
| aged wiring with the same (or higher) rated wire. |
| Inoperative platen. | To check platen: |
|
| Use an Ohm meter to test resistance of the platen |
|
| heater (disconnect 1 wire to isolate heater). Correct |
|
| cold resistance for heating element of platen are as |
|
| follows: |
|
| 120 Volts, 1750 Watts - 7.8 Ohms |
|
| 208 Volts, 2550 Watts - 16.2 Ohms |
|
| 230 Volts, 1900 Watts - 26.5 Ohms |
|
| |
|
| at 208V/300 Watts. |
P/N 1010729 Rev. C 05/04 | 13 |