Variety Steamer

 

 

 

 

 

 

Troubleshooting (continued)

 

 

 

 

 

Problem

Possible Cause

Corrective Action

 

Unit heats but there is little

Insufficient or excessive calcium/mineral

Verify that a thin layer of calcium/mineral

 

or no steam produced

buildup on generator surface.

deposits is present on the Generator sur-

 

and/or

 

face. Refer to the Maintenance section of

 

 

this manual.

 

The product requires more

Black Manifold O-ring is worn, damaged,

Replace the Black Manifold O-ring if worn,

 

steaming than usual.

or missing.

damaged, or missing.

 

(Continued)

Low Generator temperature.

Verify Generator surface temperature is at

 

 

least 380° F (193° C),

 

 

 

 

Steam leaks out of the

Black Manifold O-ring is damaged or

Replace the Black Manifold O-ring if worn,

 

sides of the unit.

missing.

damaged, or missing.

 

Black Manifold is difficult

Black Manifold not being removed and

Remove and Clean the Black Manifold

 

to remove or re-install

cleaned daily as required.

Daily according to the Maintenance section

 

onto the Generator.

 

of this manual.

 

 

Black Manifold O-ring is damaged or

Replace the Black Manifold O-ring if dam-

 

 

worn.

aged or worn.

 

 

Black Manifold O-ring is not being lubri-

Lubricate the Black Manifold O-ring daily

 

 

cated daily with Petro Gel.

according to the Maintenance section of

 

 

 

this manual.

 

Unit floods over night

Solenoid valve is being held open by

Attempt to flush the debris out of the valve

 

and/or continues to steam

debris from the building’s water line pip-

by operating the unit on a number of cycles

 

even when just in ready

ing.

and then letting it rest. If the unit still

 

mode.

 

leaks, contact your maintenance person or

 

There is no pre-strainer/filter on the water

 

 

line just before the unit.

Authorized Service Agency.

 

 

 

 

 

P/N 1010649 Rev. E 03/07

17

Page 17
Image 17
Antunes, AJ VS-200aSb owner manual Variety Steamer