To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equipment should be performed by qualified service personnel. The unit should be unplugged when servicing, except when electrical tests are required. Use extreme care during electrical circuit tests. Live circuits will be exposed.

Problem

Possible Cause

Corrective Action

Power On/Off switch is

The power cord is not correctly plugged

Plug the power cord in correctly.

turned on, but the Switch

in.

 

Indicator Light is still off

 

 

The power cord and/or electrical plug is

Inspect electrical wire, plug, and recep-

and the unit is not heating

damaged.

tacle.

up.

 

 

The main electrical panel circuit breaker

Reset circuit breaker. Contact your main-

 

 

is off, or has been tripped.

tenance person or Authorized Service

 

 

Agency if it trips again.

 

Switch is inoperable.

Contact your maintenance person or

 

 

Authorized Service Agency for service.

The unit’s main electrical

Damaged receptacle, plug, or cord; a

Turn the unit off, allow it to cool to room

panel circuit breaker trips.

loose connection or an internal compo-

temperature, and then restart the unit.

 

nent failure.

Contact your maintenance person or

 

 

Authorized Service Agency if condition

 

 

repeats.

Power On/Off switch is

Hi-Limit thermostat is tripped.

Reset the Hi-Limit according to the

turned on, the switch indi-

Inoperable Thermostat.

Operation section of this manual. If it

cator light is on, but the

 

requires continuous resetting or repair,

Inoperable Generator.

unit is not heating up.

contact your maintenance person or

Loose/burnt wiring.

 

Authorized Service Agency for service.

Unit heats but there is lit-

Water Line valve is closed.

Check that the Water Line Valve is open.

tle or no steam produced

 

 

Filter Strainer is restricted.

Check and clean the Filter Strainer as

and/or

 

described in the Maintenance section of

 

this manual.

 

 

The product requires more

Quick Disconnect is not fully engaged at

Remove and re-engage the Quick

steaming than usual.

rear of unit or is damaged.

Disconnect Insert firmly until a “click” is

 

 

heard. Replace if damaged.

 

Low or no water pressure in water line.

Remove the Quick Disconnect Insert from

 

 

the rear of the unit. While holding over a

 

 

bucket, press the “white” plastic tip. Strong

 

 

Water flow should be noted. If so, recon-

 

 

nect firmly into unit. If

 

Spray Tube is restricted.

Remove and clean the Spray Tube accord-

 

 

ing to the Daily Maintenance procedures

 

 

found in this manual.

 

Black Manifold orifices are restricted.

Remove and clean the Black Manifold

 

 

according to the Daily Maintenance proce-

 

 

dures found in this manual.

 

Unit is not being cleaned daily and/or

Clean unit Daily according to the Daily

 

properly.

maintenance procedures found in this

 

 

manual.

 

Improper water pressure to unit.

Verify that a Water Pressure Regulator is

 

 

installed and set to 20-25 PSI.

 

 

 

 

16

P/N 1010649 Rev. E 03/07

Page 16
Image 16
Antunes, AJ VS-200aSb owner manual Troubleshooting, Problem Possible Cause Corrective Action