Variety STeamer
Troubleshooting
Warning
To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equipment should be performed by qualified service personnel. The unit should be unplugged when servicing, except when electrical tests are required. Use extreme care during electrical circuit tests. Live circuits will be exposed.
Problem | Possible Cause | Corrective Action | |
Power On/Off switch is | The power cord is not correctly plugged | Plug the power cord in correctly. | |
turned on, but the Switch | in. |
| |
Indicator Light is still off |
|
| |
The power cord and/or electrical plug is | Inspect electrical wire, plug, and recep- | ||
and the unit is not heating | damaged. | tacle. | |
up. |
|
| |
The main electrical panel circuit breaker | Reset circuit breaker. Contact your main- | ||
| |||
| is off, or has been tripped. | tenance person or Authorized Service | |
|
| Agency if it trips again. | |
| Switch is inoperable. | Contact your maintenance person or | |
|
| Authorized Service Agency for service. | |
The unit’s main electrical | Damaged receptacle, plug, or cord; a | Turn the unit off, allow it to cool to room | |
panel circuit breaker trips. | loose connection or an internal compo- | temperature, and then restart the unit. | |
| nent failure. | Contact your maintenance person or | |
|
| Authorized Service Agency if condition | |
|
| repeats. | |
Power On/Off switch is | Reset the | ||
turned on, the switch indi- | Inoperable Thermostat. | Operation section of this manual. If it | |
cator light is on, but the |
| requires continuous resetting or repair, | |
Inoperable Generator. | |||
unit is not heating up. | contact your maintenance person or | ||
Loose/burnt wiring. | |||
| Authorized Service Agency for service. | ||
Unit heats but there is lit- | Water Line valve is closed. | Check that the Water Line Valve is open. | |
tle or no steam produced |
|
| |
Filter Strainer is restricted. | Check and clean the Filter Strainer as | ||
and/or |
| described in the Maintenance section of | |
| this manual. | ||
|
| ||
The product requires more | Quick Disconnect is not fully engaged at | Remove and | |
steaming than usual. | rear of unit or is damaged. | Disconnect Insert firmly until a “click” is | |
|
| heard. Replace if damaged. | |
| Low or no water pressure in water line. | Remove the Quick Disconnect Insert from | |
|
| the rear of the unit. While holding over a | |
|
| bucket, press the “white” plastic tip. Strong | |
|
| Water flow should be noted. If so, recon- | |
|
| nect firmly into unit. If | |
| Spray Tube is restricted. | Remove and clean the Spray Tube accord- | |
|
| ing to the Daily Maintenance procedures | |
|
| found in this manual. | |
| Black Manifold orifices are restricted. | Remove and clean the Black Manifold | |
|
| according to the Daily Maintenance proce- | |
|
| dures found in this manual. | |
| Unit is not being cleaned daily and/or | Clean unit Daily according to the Daily | |
| properly. | maintenance procedures found in this | |
|
| manual. | |
| Improper water pressure to unit. | Verify that a Water Pressure Regulator is | |
|
| installed and set to | |
|
|
| |
| 16 | P/N 1010649 Rev. E 03/07 |