Maintenance and Technical Specifications 3-5

Table 3-1. Troubleshooting (Continued)

Problem

Possible Causes

Possible Solutions

 

 

 

Scanner emits 4 short high beeps

Scanner has not completed USB

Wait several seconds and scan

while attempting to scan.

initialization.

again.

 

 

 

Bar code is decoded, but data is not

Scanner is not programmed for the

Scan the appropriate host

transmitted to the host.

correct host type.

parameter bar codes.

 

 

 

 

Interface cable is loose.

Ensure all cable connections are

 

 

secure.

 

 

 

 

If 4 long low beeps are heard, a

Ensure the scanner's

 

transmission error was detected.

communication parameters match

 

 

the host's setting.

 

 

 

 

If 5 long low beeps are heard, a

Ensure the scanner's conversion

 

conversion or format error was

parameters are properly

 

detected.

configured.

 

 

 

Scanned data is incorrectly

Scanner is not programmed to

Ensure proper host is selected.

displayed on the host.

work with the host.

 

For RS-232, ensure the scanner's

 

 

 

 

communication parameters match

 

 

the host's settings.

 

 

 

 

 

For a Keyboard Wedge

 

 

configuration, ensure the system is

 

 

programmed for the correct

 

 

keyboard type, and the CAPS

 

 

LOCK key is off.

 

 

 

 

 

Ensure editing options (e.g., UPC-

 

 

E to UPC-A conversion) are

 

 

properly programmed.

 

 

 

Scanner emits short high/short

RS-232 receive error.

Normal during host reset.

high/short high/long low beep

 

Otherwise, ensure the scanner's

sequence when it is not in use.

 

RS-232 parity setting matches the

 

 

host setting.

 

 

 

Scanner emits long low/long high

Input error or ’Cancel’ bar code is

Ensure the correct numeric bar

beep sequence while it is being

scanned.

codes, that are within range for the

programming.

 

parameter that is being

 

 

programmed, are being scanned.

 

 

 

Scanner emits short low/short high/

Out of ADF parameter storage

Erase all rules and re-program with

short low/short high beep sequence

space.

shorter rules.

while it is being programming.

 

 

 

 

 

Page 43
Image 43
Wasp Bar Code WLS 8400 FZ, WLS 8400 ER manual Troubleshooting