AOC IN1510, IN1222, IN1710, IN1422 operation manual Rack Mounting, Installation Procedure

Models: IN1710 IN1222 IN1510 IN1422

1 25
Download 25 pages 51.97 Kb
Page 6
Image 6

5

RACK MOUNTING

The IN1222 / IN1510 and IN1422 / IN1710 may be mounted in a standard 19" equipment rack using the appropriate mounting hardware and procedure listed below:

IN1222 / IN1510 - Use the IN9083 Rack Ears - 1 U high (optional, not included with units). The IN9083 Rack Mounting kit includes two rack ears and four mounting screws which are slightly longer than the original case screws.

IN1422 / IN1710 - Use the IN9123 Rack Ears (included with each unit). The IN9123 Rack Mounting Kit includes two rack ears and six mounting screws which are slightly longer than the original case screws.

Installation Procedure

The IN1222 / IN1510 and IN1422 / IN1710 are exactly 1 U high without the feet.

If other equipment will be located in the space immediately below the scan doubler /

decoder, the installer may have to remove the feet from the bottom of the case before mounting the unit in the equipment rack.

1.Remove power from the scan doubler / decoder.

2.Remove the case screws and retain for future use.

3.Place the rack ears along each side of the case, aligning the rack ear holes with the holes in the side of the case.

4.Use the provided mounting screws to attach the rack ears to the scan doubler / decoder case.

5.Mount the unit in a 19" EIA standard equipment rack using standard rack mounting screws.

The shorter original case screws must be used to hold together the case if the rack

ears are ever removed. If the longer screws are used in the case without the rack

ears, they will extend too far into the unit, causing serious damage to the internal circuitry. This type of damage is not covered under warranty.

©1994 - INLINE, INC.

IN1222 / IN1422 / IN1510 / IN1710 OPERATIONS MANUAL - REV. 2 12/04/99

Page 6
Image 6
AOC IN1510, IN1222, IN1710, IN1422 operation manual Rack Mounting, Installation Procedure