Technical Specifications

The following table contains the specifications for the H10.

Item

Specification

 

 

INPUT

 

 

 

Input Voltage Range for Opera-

92V - 145V

tion (on utility)

 

 

 

Nominal Voltage

120 Vac

 

 

Allowable Input Frequency for

47 - 63 Hz

Operation (on utility)

 

 

 

Rated Input Current

12 Amps

 

 

Input Circuit Breaker Rating

15 Amps

 

 

OUTPUT

 

 

 

Number of Outlets

12 (all outlets are surge pro-

 

tected, conditioned, and regu-

 

lated)

 

 

Outlet type

NEMA 5-15R

 

 

Rated VA Capacity

1000VA

 

 

Rated Watt Capacity (continuous)

1000 Watts

 

 

Rated Output Current

12 Amps

 

 

SURGE PROTECTION

 

 

 

Let-Through Voltage Rating

<40 Volts

 

 

Peak Surge Current (NM + CM)

230KA

 

 

Data Line Protection Jacks (split-

Single-line 2-wire phoneline

ter)

protection for phone, modem, or

 

fax.

 

 

Coax

 

 

 

MISCELLANEOUS

 

 

 

DC Trigger

Two 3.5mm mini-jack plugs

 

(5-30V)

 

 

EMI/RFI

40-100dB at 100KHz-30MHz

 

 

Total Surge Joules

4720

 

 

- 13 -

Page 21
Image 21