Maintenance
Air filter
Please check and clean the air filter periodically. When the indicators or a message prompts you to clean the air filter, comply with it as soon as possible. Replace the air filter when it is damaged or too soiled. To prepare a new air filter, contact your dealer and tell the air filter type number.
Type number : MU03602
When you replace the lamp, please replace the air filter. An air filter of specified type will come together with a replacement lamp for this projector.
Cleaning the air filter |
| |
1. | Turn the projector off, and unplug the power |
|
cord. Allow the projector to sufficiently cool down. |
| |
2. | Use a vacuum cleaner on and around the | The filter cover |
filter cover. | ||
3. | While supporting the projector with one hand, |
|
use your other hand to pull the filter cover |
|
forward in the direction of the arrow.
4. Use a vacuum cleaner for the filter ventilation of the projector. And clean the air filter that is set
at one side of the filter cover by using a vacuum cleaner over the other side of the filter cover. Please replace the air filter when it is damaged or too soiled. When the air filter is set, take its half moon shape cut part to the swelled part of the filter cover.
5.
6. Turn the projector on and reset the filter time using the FILTER TIME item in the EASY MENU.
(1)Press the MENU button to display a menu.
(2)Point at the “FILTER TIME” using the ▼/▲ button, then press the ► button. A dialog will appear.
(3)Press the ▲ button to select “RESET” on the dialog. It performs resetting the filter time.
WARNING ►Before taking care of the air filter, make sure the power cable is not plugged in, then allow the projector to cool sufficiently.
►Use only the air filter of the specified type. Do not use the projector without the air filter or the filter cover. It could result in a fire or malfunction to the projector. ►Clean the air filter periodically. If the air filter becomes clogged by dust or the like, internal temperatures rise and could cause a fire, a burn or malfunction to the projector.
NOTE • Please reset the filter time only when you have cleaned or replaced the air filter, for a suitable indication about the air filter.
•The projector may display the message such as “CHECK THE AIR FLOW” or turn off the projector, to prevent the internal heat level rising.
59