Auger Shaft

NOTE: To grease auger shaft, remove shear bolt nuts, and shear bolts. Apply grease at the grease zerks and then turn the auger shaft.

Replace shear bolts per instructions in Shear Bolts on page 26.

Grease Oil

OS7135

OS0642

OS7140

Remove corrosion from battery terminals and cable connections with a wire brush, then wash with a weak baking soda solution.

After cleaning, apply a thin coat of grease or petroleum jelly to terminals and cable ends to retard corrosion.

Replace Fuse (926312, 313, 316)

1.Remove the two screws and the cover plate from beneath the battery.

Cover plate and

OS7450

OS7145

Figure 20

Clean Battery (926312, 313, 316)

WARNING: AVOID INJURY. Read and understand the entire Safety section before proceeding.

IMPORTANT: Battery is maintenance-free. Do not tamper with or attempt to open battery. See SERVICE AND ADJUSTMENTS on page 26 for charging procedures.

Terminals

Keep battery and its terminals clean.

IMPORTANT: Remove battery from unit before cleaning.

mounting screws.

Figure 21

2.Locate the fuse holder on the wiring harness and remove the fuse.

3.Install a new fuse of the same amp- rating and type.

GB - 25