7. TECHNICAL INFORMATION

 

 

 

 

24 MFFI

 

24 RFFI SYSTEM

 

 

 

 

 

 

 

Certification

 

 

 

63AT4528

 

63AT4528

Category

 

 

 

II2H3B/P

 

II2H3B/P

Thermal Capacity min/max

 

 

kW

8/24

 

8/24

Usable Thermal Power min/max (30/40°C)

kW

8.8/26.1

 

8.8/26.1

Usable Thermal Power min/max (60/80°C)

kW

7.9/23.3

 

7.9/23.3

Usable Thermal Power min/max (30/50°C)

kW

-/24.5

 

-/24.5

Power for Hot Water Production min/max

kW

7.9/23.3

 

7.9/23.3

Efficiency at Nominal Thermal Capacity (30/50°C)

%

102.2

 

102.2

Efficiency at 30% of Nominal Thermal Capacity (47°C of return)

%

96.4

 

96.4

Efficiency at 30% of Nominal Thermal Capacity (30°C of return)

%

103.6

 

103.6

Gas Consumption after 10 Minutes*

m3

0.42

 

0.42

Maximum Heat Loss to the Casing (T=50°C)

%

0.6

 

0.6

Flue Heat Loss with Burner Operating

%

2.1

 

2.1

Flue Heat Loss with Burner Off

%

0.2

 

0.2

Maximum Discharge of Fumes

Kg/h

35.1

 

35.1

Maximum Temperature of Discharge Fumes

°C

66.7

 

66.7

Temperature of Discharge Fumes when Heating 30/40°C (1 m of coax.)

°C

42.9

 

42.9

Minimum Room Temperature

 

°C

5

 

5

Heating Temperature min/max (High Temperature range)

°C

42/82

 

42/82

Heating Temperature min/max (Low Temperature range)

°C

30/75

 

30/75

Temperature of Water for Domestic Use min/max

°C

36/56

 

36/56

Class NOX

 

 

 

5

 

5

CO2 Content

 

 

%

9.3

 

9.3

O2 Content

 

 

%

4

 

4

CO Content

 

 

ppm

53.5

 

53.5

Inlet Pressure/Methane Gas G20 (boiler at maximum)

mbar

20

 

20

Inlet Pressure/Liquid Gas G30 - G31 (boiler at maximum)

mbar

30

 

30

Residual Discharge Head

 

 

mbar(Pa)

0.65(64)

 

0.65(64)

Maximum Head Loss on Water Side (T=20°C)

mbar

200

 

200

Residual Head of System (60/80°C)

bar

0.2

 

0.2

Maximum Heating Pressure

 

bar

3

 

3

Maximum Water Content in System

l

130

 

130

Expansion Vessel Capacity

 

 

l

7

 

7

Expansion Vessel Pre-load Pressure

bar

1

 

1

Pressure of Water for Domestic Use min/max

bar

0.2/8-10

 

0.2/8-10

Nominal Capacity of Hot Water for Heating (residual head 0.25 bar)

l/h

820

 

820

D.H.W. Flow Rate:

T=25°C

l/min

13.4

 

---

 

T=30°C

l/min

11.1

 

---

 

T=35°C

l/min

9.6

 

---

D.H.W. Flow Minimum Rate

 

 

l/min

2.5

 

---

Quantity of Condensed Water with a (30/40°C)

l/h

1.8

 

1.8

pH Condensation Value

 

 

 

3.5÷4

 

3.5÷4

Electrical Supply

 

 

V/Hz

230/50

 

230/50

Power Consumption

 

 

W

130

 

130

Protection Grade of Electrical System

IP

4XD

 

4XD

Internal Fuse Rating

 

 

A

3.15 SLOW

 

3.15 SLOW

Width

mm

 

465

 

465

Height

mm

 

890

 

890

Depth

mm

 

385

 

385

Central Heating Connections

 

BSP

3/4

 

3/4

Domestic Hot Water Connections

BSP

1/2

 

1/2

Gas Connection

 

 

BSP

3/4

 

3/4

Net Weight

 

 

Kg

45

 

44.5

 

 

 

 

 

 

 

G.C. Number

 

 

 

41-116-17

 

41-116-03

 

 

 

 

 

Manufacturer:

Merloni TermoSanitari SpA - Italy

 

*Calculated at 70% maximum output

Commercial subsidiary:

MTS (GB) LIMITED

 

 

 

 

 

MTS Building

 

 

 

 

 

Hughenden Avenue

 

 

 

 

 

High Wycombe

 

 

 

 

 

Bucks HP13 5FT

 

 

 

 

 

Telephone: (01494) 755600

 

 

 

 

 

Fax: (01494) 459775

 

 

 

 

 

Internet: http://www.mtsgb.ltd.uk

 

 

 

 

 

E-mail: info@mtsgb.ltd.uk

 

 

 

 

 

Technical Service Hot Line: (01494) 539579

 

 

23 99 84 1439 112

Page 24
Image 24
Ariston 47-116-17 installation instructions Technical Information, Mffi Rffi System

47-116-17 specifications

The Ariston 47-116-17 is a blend of advanced technology and user-centric design, setting a new standard in home appliances. This washing machine stands out not only for its robust performance but also for its energy-efficient features, making it a top choice for environmentally conscious consumers.

One of the key features of the Ariston 47-116-17 is its impressive capacity. With a drum that can hold up to 7 kg of laundry, it accommodates a variety of household needs, from small loads to larger family washes. This ensures that users can complete their laundry tasks efficiently without multiple wash cycles.

The machine is equipped with a powerful motor that delivers effective cleaning while minimizing noise levels. This is especially beneficial for households where laundry is often done at night or during quiet hours. The appliance operates discreetly, allowing users to run cycles without disturbing the peace of the home environment.

Technology is at the forefront of the Ariston 47-116-17, featuring a comprehensive range of washing programs tailored to suit different fabric types and soil levels. The machine includes specialized settings for delicate fabrics, wool, and heavily soiled garments, ensuring that every item is treated with care. This versatility allows users to maintain the quality of their clothes while achieving optimal cleaning results.

Energy efficiency is another significant characteristic of the Ariston 47-116-17. It boasts a high energy rating, which translates to lower electricity bills and a reduced carbon footprint. The appliance also incorporates water-saving technology, which not only conserves water but also enhances overall efficiency during the wash cycle.

Additionally, the machine is designed with user convenience in mind. Its intuitive control panel makes it easy for users to select the desired programs and settings, even for those who may not be tech-savvy. The digital display provides clear information on remaining wash time, cycle status, and any error messages that may arise.

In conclusion, the Ariston 47-116-17 is a reliable, efficient, and user-friendly washing machine that meets the diverse needs of modern homes. Its combination of capacity, advanced cleaning technologies, energy efficiency, and convenience features makes it a noteworthy addition to any laundry room. Users can enjoy the benefits of powerful performance with the peace of mind that comes from choosing an environmentally responsible appliance.