1.3.OVERALL VIEW

24 MFFI

24 RFFI SYSTEM

LEGEND:

1.Flue connector

2.Heating flow temperature probe

3.Mixer

4.Condensate collector

5.Expansion vessel

6.Condensate trap (tube)

7.Condensate trap

8.Diverter valve

9.Main circuit flow switch

10.Domestic hot water temperature probe

11.Control panel

12.Gas valve

13.Domestic hot water flow switch

14.Drain valve

15.Safety valve (3 bar)

16.Secondary heat exchanger

17.Circulation pump with automatic air release valve

18.Heating return temperature probe

19.Sealed combustion chamber

20.Combustion chamber inspection hatch

21.Fan

22.Ignition and detection electrode

23.Main heat exchanger (aluminium)

24.Automatic by-pass

25.Silencer

2. INSTALLATION

The technical information and instructions provided herein below are intended for the installer so that the unit may be installed correctly and safely.

2.1.REFERENCE STANDARDS

The installation and initial start-up of the boiler must be by a CORGI Approved Installer in compliance with the installation standards currently in effect, as well as with any and all local health and safety standards i.e. CORGI.

This appliance must be installed by a competent installer in accordance with the current Gas Safety (installation & use) Regulations.

The installation of this appliance must be in accordance with the relevant requirements of the current Gas Safety (installation & use) Regulations, the Local Building Regulations, the current I.E.E. Wiring Regulations, the byelaws of the local water authority, and in Scotland, in accordance with the Building Standards (Scotland) Regulation and Health and Safety document No. 635 “Electricity at work regs. 1989”. Installation should also comply with the following British Standard Codes of Practice:

Low pressure

 

 

pipes

BS 6891

1988

 

 

 

Boilers of rated input

 

 

not exceeding 60 kW

BS 6798

1987

 

 

 

Forced circulation hot

 

 

water system

BS 5449

1990

Installation of gas hot water

 

 

supplies for domestic purposes

 

( 2nd family gases)

BS 5546

1990

Flues

BS 5440-1

1990

 

 

 

Air supply

BS 5440-2

1989

 

 

 