Image 6
2.7 CONNECTION OF MAINS

www.tradeplumbing.co.uk Call Sales On 08708034288

2.7 CONNECTION OF MAINS

For floor standing models:

WATER SUPPLY

On the front of the unit there is a label to identify the connection ports.

 

Please check this before making any connection to the unit.

ST PROTECH 50-80-100

PRESSURE + TEMPERATURE

RELIEF VALVE

COLD

MAINS-IN 15/22mm

15mm

EXPANSION

VESSEL

COMBINATION

VALVE

HOT SUPPLY

15/22mm

EXPANSION

RELIEF

PIPE

TUNDISH

For units up to 300 litres it is recommended that all mains cold water supply pipe work is a minimum of 22mm, with the exception of model ST 50 ProTech where 15mm can be used. For 500 litre models the supply should be 28mm. An isolating valve should be installed between the cold water supply and the cylinder for servicing. ALL PIPEWORK MUST BE FLUSHED TO AVOID DAMAGE TO THE CONTROL VALVES.

Please refer to FIGS. 2.1, 2.2, 2.3, 2.4, 2.5 for a suggested installation layout.

22mm

MAX. 100mm

FIG. 2.1

STD PROTECH 100

STD/STD PROTECH/ITD 125-150-210-300 DIRECT

 

COLD

 

MAINS-IN

COMBINATION

22mm

 

VALVE

 

 

EXPANSION

 

VESSEL

 

PRESSURE + TEMPERATURE

 

RELIEF VALVE

HOT SUPPLY

 

22mm

 

EXPANSION RELIEF

 

PIPE

 

SECONDARY

 

RETURN

 

TUNDISH

 

22mm

 

DRAIN

 

MAX. 100mm

www.tradeplumbing.co.uk Call Sales On 08708034288FIG. 2.2

6For floor standing models:WATER SUPPLYPlease check this before making any connection to the unit.ST PROTECH 50-80-100STD PROTECH 100Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background