www.tradeplumbing.co.uk Call Sales On 08708034288

5.FAULT FINDING

FAULT

POSSIBLE CAUSES

REMEDY

 

 

 

 

 

1)

Mains cold water

Check and open Isolating

 

 

supply shut off

and/or stop valve. Check

 

 

 

water, Local Water Authority

NO HOT WATER

 

 

 

2)

Line strainer

Turn off mains water supply,

FLOW

 

blocked

remove line strainer and

 

 

 

clean

 

 

 

 

 

3)

Cold Water

Check direction of flow

 

 

Combination valve

arrows on valve, refit in

 

 

fitted incorrectly

correct position if necessary

 

1)

Low mains water

Check pressure, consult

 

 

pressure

Local Water Authority if

 

 

 

necessary

REDUCED FLOW

 

 

 

2)

Line strainer

Turn off mains water supply,

RATE

 

partially blocked

remove line strainer and

 

 

 

clean

 

 

 

 

 

3)

Size of service

Increase to size stated on

 

 

pipe too small

page 6

 

 

 

 

 

1)

Direct immersion

Check immersion heater,

 

 

heater is not

switch on if necessary

 

 

switched on

 

 

 

 

 

 

2)

Direct thermal

Test thermostat operation

 

 

cut-out has

and wiring, if faulty,

 

 

operated

correct/replace. Reset cut-out

WATER FROM

 

 

 

3)

Boiler programmer

Check switch on domestic

HOT TAPS

 

set to central

hot water if necessary

IS COLD

 

heating only

 

 

 

(Indirect models)

 

 

 

 

 

 

4)

Boiler is not

Check boiler operation, if

 

 

functioning

fault suspected consult

 

 

(Indirect models)

manufacturer's instructions

 

 

 

 

 

5)

Indirect thermal

Test thermostat operation

 

 

cut-out has

and wiring, if faulty,

 

 

operated

correct/replace. Reset

 

 

 

cut-out

 

 

 

 

 

6)

Motorised valve

Check wiring and operation of

 

 

jammed or not

motorised valve correct/

 

 

wired correctly

replace as necessary

 

 

(Indirect models)

 

DISCHARGE FROM

1)

Pressure above 7

Shut down boiler or immersion

PRESSURE/

 

bar, failure of

heater. Check pressure

TEMPERATURE

 

pressure reducing

reducing valve and thermal

RELIEF VALVE

 

valve. Temperature

controls. Replace if

 

 

above 90 C failure

necessary

 

 

of thermal control

 

DISCHARGE FROM

1)

Continually.

Check pressure from valve.

EXPANSION

 

Pressure reducing

Replace if over 3.5 bar

VALVE

 

valve faulty

 

 

 

 

 

2) When heater is heating.

Check charge of vessel. Re-

 

 

Faulty expansion

charge vessel to 3.5 bar or

 

 

vessel or lost charge

replace if necessary

 

 

 

 

www.tradeplumbing.co.uk Call Sales On 08708034288

21

Page 21
Image 21
Ariston Unvented Hot Water Storage Cylinders manual Fault Finding, Fault Possible Causes Remedy