ChannelMag Section 2 Installation
2.4.3 CM2/D
Dimensions and
Approximate Weight
The CM2/D is normally used with a FMX167 hydrostatic level transducer and installed as shown below. A
(4.5 liters) of gel, which should suffice for the installation of CM2/D.
The hydrostatic level transducer must be installed in a stilling well as shown, such that the level is not affected by the impact pressure of the flowing media. The hydrostatic pressure transducer may be installed with its bottom most end above any silt
Similarly to the FMX167, the CM2/D mean velocity sensor may be installed to protrude above the bottom of the channel by a suggested maximum of 0.5” (10mm), as shown in the diagram below.
The CM2/8”, 24” and 40” ChannelMag sensors are normally supplied with mounting brackets at each side. The mounting brackets are placed over two clearance slots cut into the Magnetic Enhancement Plates. Base plates with fixing screws, countersunk from the bottom side are then used to secure the CM2 ChannelMag to the Magnetic Enhancement Plates. The clearance slots allow the Magnetic Enhancements Plates to be adjusted symmetrically about the exact width of the channel. The width must be adjusted and secured before installing the ChannelMag into the channel.
Note
For CM2 ChannelMags supplied without ramps, the CM2 must be placed in a recess that must be made in the bed of the channel. The recess depth must be such that the upper surface of the ChannelMag is not higher than a suggested ½”” (12mm) above the bed of the channel, but enough
to avoid excessive silt or similar
14