HC-6000 Repair Parts
41
Component Voltage Resistance Component Voltage Resistance
Fill Valve 24Vac 18ΩFill Valve 24Vac 8.8Ω
Drain Valve 24Vac 10ΩDrain Valve 24Vac 4.1Ω
Contractor 24Vac 7-9ΩThermocouple in Heating Elements - 0.51Ω
Thermocouple in Heating Elements - 0.51Ω
208, 240, 380V, 30/33, 5/40/45/50,3/60kW 240Vac 7.4-9.1Ω
208Vac and 380Vac 3kW 220 Vac 46.0-48.6Ω380V 48/72kW 220Vac 5.2-6.3Ω
240Vac and 380Vac 3kW 240 Vac 55-58Ω480V 48/72kW 277Vac 8.1-10.0Ω
480Vac and 380Vac 3kW 277 Vac 72-78.2Ω600V 48/72kW 346Vac 12.8-15.7Ω
600Vac and 380Vac 3kW 346 Vac 112.4-122.4ΩPower Transformer
208Vac and 380Vac15/30kW 220Vac 9.2-10.7Ω208Vac 18Ω across H1-H2
240Vac 15/30kW 240Vac 10.9-12.6Ω240Vac 21Ω across H1-H3
480Vac 15/30kW 277Vac 14.5-16.8Ω277Vac 24Ω across H1-H4
600Vac 15/30kW 346Vac 22.7-26.3Ω380Vac 40Ω across H1-H5
208Vac and 380Vac9/18kW 220Vac 15.3-17.7Ω480Vac 53Ω across H1H6
240Vac 9/18kW 240Vac 18.2-21.1Ω600Vac 97Ω across H1-H2
480Vac 9/18kW 277Vac 24.3-28.2Ω208Vac 1Ω across X1-X2
600Vac 9/18kW 346Vac 37.9-43.9Ω240Vac 1Ω across X1-X2
120Vac
13.6Ω across H1-H2
15.1Ω across H3-H4
277Vac 1Ω across X1-X2
208Vac 22Ω across H1-H2 380Vac 1Ω across X1-X2
240Vac 29Ω across H1-H2 480Vac 1Ω across X1-X2
380Vac 77Ω across H1-H2 600Vac 1Ω across X1-X4
480Vac 125Ω across H1-H2
600Vac 194Ω across H1-H2
Power Transformer
(secondary)
All
Voltage
0.6Ω across X1-X2
0.4Ω across X1-X2
Secondary Loop
Note: All measurements should be made with the main power off and
the wires to the component being tested disconnected.
Resistance Value of 6100/6300 Components
Heating Elements
Power Transformer
Resistance Value of 6500-6700 Comoponents
Heating Elements
Primary Loop