6.2.9Enabling the WriteCache
You may enable the RAID controller’s WriteCache option to improve the data transmission performance.
When you enable WriteCache, you may lose data when a power interruption occurs while transmitting or exchanging data among the drives.
To enable WriteCache:
1.From the Management Menu, select Objects > Adapter, then press <Enter> to display the adapter properties.
2.Select WriteCache, then press <Enter> to turn the option On (enabled).
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
|
|
|
|
|
|
| Adapter 0 |
|
| ||
|
|
|
|
|
| Rebuild Rate |
| = | 30 |
|
|
|
|
| ObjectsChk Const Rate = | 30 |
|
| |||||
Management | MenuAdapter |
| Drive | FGI Rate | = | 30 |
|
| |||
Configure | Virtual |
| BGI Rate | = | 30 |
|
| ||||
Initialize | Physical |
| DriveDisk WC | = | Off |
| |||||
Objects |
|
|
|
|
| Read Ahead | = | On |
| ||
|
|
|
|
|
| ||||||
Rebuild |
|
|
|
|
|
| |||||
|
|
|
|
| Bios State | = | Enable |
| |||
Check Consistency |
|
|
|
|
| ||||||
|
|
|
| Stop On Error | = | No |
| ||||
|
|
|
|
|
|
| |||||
|
|
|
|
|
| Fast Init | = | Enable |
| ||
|
|
|
|
|
| Auto Rebuild | = | On |
| ||
|
|
|
|
|
| Auto Resume | = | Enable |
| ||
|
|
|
|
|
| Disk Coercion | = | 1GB |
| ||
|
|
|
|
|
| Factory Default |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
Disk Write Cache - Off(Write Through) or On(Write Back)
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
3.When finished, press any key to continue.
Chapter 6: RAID configuration |