ATEN Technology CL-1216, CL-1208 user manual Firmware Upgrade Recovery

Models: CL-1216 CL-1208

1 73
Download 73 pages 4.78 Kb
Page 63
Image 63
Firmware Upgrade Recovery

The Firmware Upgrade Utility

Firmware Upgrade Recovery

There are basically three conditions that call for firmware upgrade recovery:

MWhen you invoke Firmware Upgrade Mode (see p. 50), but decide not to proceed with the upgrade.

MWhen the Mainboard firmware upgrade fails.

MWhen the I/O firmware upgrade fails.

To perform a firmware upgrade recovery, do the following:

1.Power off the switch. If it is part of a daisy chain, disconnect it from the chain.

2.Connect the Firmware Upgrade Cable to its Firmware Upgrade Port.

3.Slide the Firmware Upgrade Recovery Switch to the Recover position.

4.Power the switch back on and repeat the upgrade procedure.

5.After the switch has been successfully upgraded, power it off, and slide the Firmware Upgrade Recovery Switch back to the Normal position.

6.If the switch is part of a daisy chain, replace it in the chain.

7.Power the switch back on

55

2005-04-26

Page 63
Image 63
ATEN Technology CL-1216 Firmware Upgrade Recovery, Connect the Firmware Upgrade Cable to its Firmware Upgrade Port