F4 ADM:

CL-1208 / CL-1216 User Manual

F4 ADM:

F4 is an Administrator only function. It allows the Administrator to configure and control the overall operation of the OSD. To change a setting Double Click it; or use the Up and Down Arrow Keys to move the highlight bar to it then press [Enter].

After you select an item, a submenu with further choices appears. Double Click the choice you want, or move the Highlight Bar to it then press [Enter]. An icon appears before the selected choice so that you know which one it is. The settings are explained in the following table:

Setting

Function

SET

This function is used to set Usernames and Passwords for the

USERNAME

Administrator and Users:

AND

 

PASSWORD

1. One Administrator and four User passwords can be set.

 

2. After you select the Administrator field or one of the User fields,

 

a screen that allows you to key in your username and

 

password appears. The username and password may be up

 

to 15 characters long, and can consist of any combination of

 

letters and numbers (A - Z, 0 - 9).

 

3. For each individual, key in the Username and Password, then

 

press [Enter].

 

4. To modify or delete a previous Username and/or Password,

 

use the backspace key to erase individual letters or numbers.

 

 

SET LOGOUT

If there is no input from the console for the amount of time set

TIMEOUT

with this function, the Operator is automatically logged out. A login

 

is necessary before the console can be used again.

 

This enables other Operators to gain access to the computers

 

when the original Operator is no longer accessing them, but has

 

forgotten to log out. To set the timeout value, key in a number

 

from 1 - 180 minutes, then press [Enter]. If the number is 0 [zero],

 

this function is disabled. Default is 0 (disabled).

 

 

(Table continues on next page)