4. OSD Operation
(Continued from previous page.)
Setting | Function |
|
|
SCAN MODE | Selects which Ports are available for scanning. There are six |
| choices: |
| ALL - All the Ports which have been set Accessible (F5) |
| QVIEW - Only those Ports which have been set Accessible |
| (F5) and have been selected for Quick View Scanning (F7) |
| POWERED ON - Only those Ports which have been set |
| Accessible (F5) and are Powered On |
| POWERED ON + QVIEW - Only those Ports which have |
| been set Accessible (F5) and have been selected for Quick |
| View Scanning (F7) and are Powered On |
| QVIEW + NAME - Only those Ports which have been set |
| Accessible (F5) and have been selected for Quick View |
| Scanning (F7) and have been named (F2) |
| NAME - Only those Ports which have been set Accessible |
| (F5) and have been named (F2). |
|
|
SCAN DURATION | Determines how long the display dwells on each port when it |
| cycles through the selected ports in Quick View Scan Mode. |
| Key in a value from |
| Default is 3 seconds. |
|
|
PRIVATE MODE | The [Enter] key is a toggle that enables/disables Private |
| Mode for the currently selected port. When Private Mode is |
| enabled, the other Console cannot access the port, and its |
| monitor shows a blank screen with a P symbol displayed in |
| front of the Port ID to indicate Private Mode. When you have |
| finished making your selections, press [Esc] to return to the |
| OSD Main Menu. |
|
|
RESTORE DEFAULT | This function is used to undo all User changes and return the |
VALUES | setup to the original factory default settings except for the |
| Names that were assigned to Ports, which are retained. |
|
|
MOUSE BUTTON | This function allows you to set the mouse for right or left |
SETUP | handed operation. Use [Enter] to toggle between the two. |
23