4. OSD Operation

(Continued from previous page.)

Setting

Function

 

 

SCAN MODE

Selects which Ports are available for scanning. There are six

 

choices:

 

Š ALL - All the Ports which have been set Accessible (F5)

 

Š QVIEW - Only those Ports which have been set Accessible

 

(F5) and have been selected for Quick View Scanning (F7)

 

Š POWERED ON - Only those Ports which have been set

 

Accessible (F5) and are Powered On

 

Š POWERED ON + QVIEW - Only those Ports which have

 

been set Accessible (F5) and have been selected for Quick

 

View Scanning (F7) and are Powered On

 

Š QVIEW + NAME - Only those Ports which have been set

 

Accessible (F5) and have been selected for Quick View

 

Scanning (F7) and have been named (F2)

 

Š NAME - Only those Ports which have been set Accessible

 

(F5) and have been named (F2).

 

 

SCAN DURATION

Determines how long the display dwells on each port when it

 

cycles through the selected ports in Quick View Scan Mode.

 

Key in a value from 1–255 seconds, then press [Enter].

 

Default is 3 seconds.

 

 

PRIVATE MODE

The [Enter] key is a toggle that enables/disables Private

 

Mode for the currently selected port. When Private Mode is

 

enabled, the other Console cannot access the port, and its

 

monitor shows a blank screen with a P symbol displayed in

 

front of the Port ID to indicate Private Mode. When you have

 

finished making your selections, press [Esc] to return to the

 

OSD Main Menu.

 

 

RESTORE DEFAULT

This function is used to undo all User changes and return the

VALUES

setup to the original factory default settings except for the

 

Names that were assigned to Ports, which are retained.

 

 

MOUSE BUTTON

This function allows you to set the mouse for right or left

SETUP

handed operation. Use [Enter] to toggle between the two.

23