CP400 & CP700 COMMERCIAL POWER AMPLIFIER

Input Wiring

OWNER'S MANUAL

Balanced Inputs

Balanced input wiring requires two conductors with shield (22-gauge is the most common). The use of crimp type spade lugs is highly recommended for permanent installations. At the input section located on the rear of the amplifier, wire the “hot”/positive lead to the “+” terminal, the “common”/negative lead to the “-” terminal and the shield/drain to the “ground” terminal (Figure 3).

The XLR inputs (+4 dB balanced line level) can be utilized with standard 3-pin XLR male to female patch cables to accommodate outputs from a mixer, equalizer, or crossover when the amplifier is used as a portable sound system amplifier.

 

 

 

 

White (+)

White (+)

 

 

 

 

 

 

 

 

 

 

 

 

Black (-)

Black (-)

 

 

 

 

 

 

 

Shield

Shield

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 3

Specifications are subject to change without notice

AtlasSound.com

1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. •

TELEPHONE: (800) 876-3333

FAX: (800) 765-3435

©2008 ATLAS SOUND LP

Printed in U.S.A.

ATS002102 RevD 2/08