32 Maintenance
© Travis Industries 4070806 100-01191_000
Bi-Weekly Maintenance (or every 10 bags of pellets) - continued
Sweep Ash Into Ashpan
WARNING : Make sure the heater has fully cooled (approximately 25 minutes) before conducting service.
Remove the two ashdump covers on the floor of the firebox using the included hook tool. Remove
the firepot and place it aside. Sweep accumulated flyash through the holes in the firebox floor into the
ashpan. Replace the covers and firepot after cleaning.
Use the included hook tool to remove the
ashdump covers (both side).
Lift the firepot out of the firebox.
Use the included brush to
sweep all flyash into the
ashpan.
Make sure to sweep flyash from
the firepot holder.