Baseboard

14.6.1 Required tools

Starting and completing the task:

key for the rack doors (if applicable)

Phillips Ph2 screw driver

Replacing the baseboard:

Phillips Ph0 screw driver

Phillips Ph1 screw driver

Phillips Ph2 screw driver

14.6.2 Starting the task

ÊPerform the following procedures:

1."Opening the rack door" on page 40

2."Locate the faulty server" on page 37

3."Shutting down the server" on page 41

4."Sliding the server out of the rack" on page 42

5."Opening the server" on page 44

6.Remove all PSUs, see "Removing the power supply unit" on page 58

7.Remove all CPUMEMRs, see "Removing the CPUMEMR" on page 190

IBefore removing the CPUMEMRs, take a note on the installation slot number for each CPUMEMR. Make sure that you reinstall the CPUMEMR in the slot it was located before the replacement.

8.Remove all expansion cards and dummy modules in PCIe slots #8 to #17, see "Expansion cards and BBU" on page 105

IBefore removing the expansion cards, take a note on the installation slot number for each card. Make sure that you reinstall the card in the slot it was located before the replacement.

RX900 S1

Maintenance Manual

277

Page 277
Image 277
Fujitsu RX900 S1 manual Maintenance Manual 277