Processors

ÊFasten the heat sink with its five captive screws. Fasten the screws alternately until they are fully tightened:

Give each screw about 4 turns at a time.

Start with screw 1 to screw 5 as indicated in figure 127 and continue with screw 1.

Torque: 0.6 Nm

10.2.8 Completing the task

ÊPerform the following procedures to complete the task:

1."Inserting the CPUMEMR in the slot" on page 186

2."Closing the server" on page 47

3."Mounting the server in the rack" on page 49

4."Bringing the server back to operation" on page 51

5.Enter the BIOS menu and enable the replaced processor.

6."Closing the rack door" on page 51

214

Maintenance Manual

RX900 S1

Page 214
Image 214
Fujitsu RX900 S1 manual Enter the Bios menu and enable the replaced processor