234 Maintenance Manual RX900 S1
Front panel and external connectors
12.2 Replacing the front panel module

12.2.1 Required tools

Starting and completing the task:
key for the rack doors (if applicable)
Phillips Ph2 screw driver
Replacing the front panel module: tool-less

12.2.2 Starting the task

ÊPerform the following procedures:
1. "Opening the rack door" on page40
2. "Shutting down the server" on page 41
3. "Sliding the server out of the rack" on page42
4. "Opening the server" on page 44
5. Remove all CPUMEMRs, see "Removing the CPUMEMR" on page190
IBefore removing the CPUMEMRs, take a note on the installation
slot number for each CPUMEMR. Make sure that you reinstall the
CPUMEMR in the slot it was located before the replacement.
6. "Removing the control panel" on page229
Authorized personnel
Authorized specialist personnel can carry out replacement tasks for
integral server components. Ask you local Fujitsu service center for
more detailed information.
VCAUTION!
Procedures indicated as "Authorized personnel only“ must be
done by Fujitsu service personnel or technicians trained by
Fujitsu for doing these tasks. Please note that unauthorized
interference with the system will void the warranty and exempt the
manufacturer from all liability.