Baseboard

14.6Replacing the baseboard

Authorized personnel

Authorized specialist personnel can carry out replacement tasks for integral server components. Ask you local Fujitsu service center for more detailed information.

VCAUTION!

Procedures indicated as "Authorized personnel only“ must be done by Fujitsu service personnel or technicians trained by Fujitsu for doing these tasks. Please note that unauthorized interference with the system will void the warranty and exempt the manufacturer from all liability.

IThe baseboard is optionally equipped with a Trusted Platform Module (TPM). This module enables programs from third party manufacturers to store key information, for example drive encryption using Windows Bitlocker Drive Encryption.

The TPM is activated via the BIOS system, see BIOS manual for the D3081 system.

VCAUTION!

Before replacing the baseboard, ask the customer whether TPM functionality is used.

If the customer is using TPM functionality, remove the TPM from the old baseboard and install it on the new baseboard. Advise the customer that he must provide you with TPM backup copies. For security reasons, the TPM must be restored/re-saved by the customer. After installing a new baseboard the TPM must be enabled. You may not clear the TPM data.