366 Maintenance Manual RX900 S1
Appendix
*1) The SAS RAID controller shall not be installed in PCIe slot #1 to #7 on the
PCI Riser when a BBU is connected because of limited length of the BBU cable.
*2) The Quad LAN card consumes twice as much I/O space as a standard
expansion card because it includes a bridge within the card. If you install this
card into slot#1 or slot#2, no I/O resource will be assigned to the onboard GbE
controller.
Emulex 4G-FCx1 Gen 1x8 8 x x x x x x x x
4G-FCx2Gen 1x88 xxxxxxxx
8G-FCx1 Gen 2x8 8 2 2 2 2 x x x x
8G-FCx2 Gen 2x8 8 2 2 2 2 x x x x
FCoE Gen 2x8 8 2 2 2 2 x x x x
Intel GbEx1 Gen 1x48 xxxxxxxxx
GbEx2 Gen 1x48 xxxxxxxxx
GbEx4 Gen 1x4 8 3 3 3 3 x x x x
10GbEx2 Gen 2x8 8 3 3 3 3 x x x x
Chipset IOH#3 IOH#4
Bus scan order 12 11 10 9 17 16 15 14 13
I/O space assigning order within
the I/O Hub (IOH)
12 12
Hot-plug y y y y n n n n n
Gen2 width x8x8x8x8x8x8x8x8x4
Slot # 9 10 11 12 13 14 15 16 17
Vendor Type PCIe Max #
Table 8: Expansion card installation recommendation I/O Hubs IOH#3 and IOH#4