Baseboard
14.3.2 Starting the task
ÊPerform the following procedures:
1."Opening the rack door" on page 40
2."Shutting down the server" on page 41
3."Sliding the server out of the rack" on page 42
4."Removing the rear cover" on page 46
5.If required to access the installation place: Remove the expansion cards, see "Expansion cards and BBU" on page 105
IBefore removing the expansion cards, take a note on the installation slot number for each card. Make sure that you reinstall the card in the slot it was located before the replacement.
14.3.3 Removing the UFM
Figure 167: Removing the UFM board
ÊRemove the SAS and BBU cable(s) for a convenient access to the mounting location of the UFM.
ÊRemove the nylon screw on the defective UFM board.
ÊDisconnect and remove the defective UFM board.
IThe metal spacer remains on the baseboard.
268 | Maintenance Manual | RX900 S1 |