Hard disk and solid state drives
6.2Replacing the HDD/SSD module
Trained personnel
VCAUTION!
●Only remove an HDD/SSD module during operation if the drive is not currently being accessed. Observe the indicators for the corresponding HDD/SSD modules, see "PRIMERGY RX900 S1 Server - Operating manual".
●Under no circumstances should you remove an HDD/SSD module while the system is in operation if you are not sure that the drive is operated by a RAID controller and belongs to a disk array that is operating in RAID level 1, 1E, 10, 5, 50, 6 or 60.
An HDD/SSD module can only be replaced during operation in conjunction with a corresponding RAID configuration.
●All HDD/SSD modules (drives) must be uniquely identified so that they can be reinstalled in their original mounting locations later. If this is not done, existing data can be lost.
6.2.1Required tools
●Starting and completing the task:
– key for the rack doors (if applicable)
●Replacing the HDD/SSD module:
84 | Maintenance Manual | RX900 S1 |