3 6Maintenance

Yearly Maintenance (or every two tons) - continued

Clean the Exhaust Blower

The exhaust blower cover is held in place with 4 screws.

Remove the side cover.

Remove the cover plate on the exhaust blower. Clean the area inside the blower, removing all flyash.

Remove these 3 nuts to expose the exhaust blower.

Use the bottle brush to disoldge any flyash near the exahust blower and in the horizontal exhaust channel. Take care to not damage the impeller on the exhaust blower.