Problem

 

 

Possible Solution

 

 

 

 

 

 

 

 

 

Power ON

 

 

Please check out voltage of adapter. (DC +5V)

 

 

Power LED does not

 

 

 

 

 

 

Ensure that power adapter correctly plugged

 

 

work

 

 

 

 

 

 

 

 

 

 

 

 

 

Select switch the emulation mode

 

 

 

 

 

- Retry self EDID read

 

 

Cannot read selected

 

 

- Check the monitor to read EDID

 

 

 

 

Select switch the real mode.

 

 

EDID

 

 

 

 

 

 

- Please check and connected the UTP cable. (Only the direct

 

 

 

 

 

 

 

 

 

 

 

type)

 

 

 

 

 

- Please check if the DVI cable is connected.

 

 

 

 

 

Select single mode switch

 

 

 

 

-

Max resolution 1920x1200@60Hz

 

 

 

 

 

- Some monitor will not support this mode.

 

 

 

 

 

Select dual mode switch

 

 

 

 

-

Max resolution 2560x1600@60Hz

 

 

Resolution Issue

 

-

Please check and connect DVI cable type (Should use DVI-Dual

 

 

 

 

 

 

cable)

 

 

 

 

 

Noise or no display

 

 

 

 

 

- Please check the DVI and optical fiber cable is connected.

 

 

 

 

 

*** The max resolution is different on to connected monitor

 

Self EDID Setting :

1)DDC function switch set to Emulation.

2)DVI cable connection between TX and display.

3)Supply power to TX (DC +5[V]).

4)LED blink -> LED ON

www.avenview.com

10

 

 

Page 10
Image 10
Avenview FO-DVI-DL-330X specifications Problem Possible Solution