Avocent 3200, 3100, 3050 manual Web Interface Operations

Models: 3200 3050 3100

1 102
Download 102 pages 61.8 Kb
Page 67
Image 67

Chapter 4: Web Interface Operations

55

 

 

NOTE: The factory default name in earlier versions contains a space that must be removed by editing the switching system name in the Appliance Overview screen of the OBWI.

6.Create one or more groups under the group container organizational unit.

7.Add the user names and target device and appliance objects to the groups you created in step 5.

8.Specify the value of any attribute being used to implement the access control attribute. For example, if you are using info as the attribute in the Access Control Attribute field and using the Notes property in the group object to implement the access control attribute, the value of the Notes attribute in Active Directory may be set to one of the three available access levels (KVM User, KVM User Admin or KVM Appliance Admin) for the group object. The members of the group may then access the appliances and target devices at the specified access level.

Page 67
Image 67
Avocent 3200, 3100, 3050 manual Web Interface Operations