AXIS 211M - I/O Terminal Connector

I/O Terminal Connector

The I/O terminal connector is used in applications such as motion detection, event triggering, time lapse recording and alarm notifications. It provides the interface to:

1 transistor output - For connecting external devices such as relays and LEDs. Con- nected devices can be activated by AXIS VAPIX AP, output buttons on the Live View page or by an Event Type. The output will show as active (shown under Event Config- uration > Port Status) if the alarm device is activated.

1 digital input - An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under Event Configuration > Port Status).

Auxiliary power and GND

Pin 4

Pin 2

Pin 3

Pin 1

Terminal connector. Note that the pins are numbered 1-4, right to left.

Function

Pin number

Notes

Specifications

 

 

 

 

GND

1

 

 

 

 

 

 

5V DC Power

2

Can be used as an alternative power supply (7-20VDC) or to power

Max load = 100mA

 

 

auxiliary equipment +5VDC (100mA).

 

 

 

 

 

Digital Input

3

Connect to GND to activate, or leave floating (or unconnected) to

Must not be exposed to voltages greater

 

 

deactivate.

than

 

 

 

20VDC

 

 

 

 

Transistor Output

4

Uses an open-collector NPN transistor with the emitter connected

Max load =100mA

 

 

to the GND pin. If used with an external relay, a diode must be

Max voltage = 24VDC

 

 

connected in parallel with the load, for protection against voltage

(to the transistor)

 

 

transients.

 

 

 

 

 

Connection diagram

AXIS 211M

5V

max. 100mA

1o

e.g. pushbutton

2o

z

3 o

4

o

34