The I/O-B ConnectorThe 4-pole I/O-B connector provides a digital rel ay switch for the control of external
surveillance devices and services; such as, lighting, annunciators, audible alarms, etc. It is
also an RS-485/422 port for the control of pan tilt devices, etc. A pinout table is provided
below.
Pinout Information
Schematic diagram - showing possible application
Pin Function
1Relay switch - pole 1. Electrically isolated from chassis and connectors.
2Relay switch - pole 2. Electrically isolated from chassis and connectors.
3RS-485/422 - B (inverting)
A half-duplex RS-485/422 interface for controlling auxiliary equipment.
4RS-485/422 - A (non-inverting)